sysfs-bus-w1 (529B)
1What: /sys/bus/w1/devices/.../w1_master_timeout_us 2Date: April 2015 3Contact: Dmitry Khromov <dk@icelogic.net> 4Description: Bus scanning interval, microseconds component. 5 Some of 1-Wire devices commonly associated with physical access 6 control systems are attached/generate presence for as short as 7 100 ms - hence the tens-to-hundreds milliseconds scan intervals 8 are required. 9 10 see Documentation/w1/w1-generic.rst for detailed information. 11Users: any user space application which wants to know bus scanning 12 interval