      1=====================================================
      2Freescale i.MX8 DDR Performance Monitoring Unit (PMU)
      3=====================================================
      4
      5There are no performance counters inside the DRAM controller, so performance
      6signals are brought out to the edge of the controller where a set of 4 x 32 bit
      7counters is implemented. This is controlled by the CSV modes programmed in counter
      8control register which causes a large number of PERF signals to be generated.
      9
     10Selection of the value for each counter is done via the config registers. There
     11is one register for each counter. Counter 0 is special in that it always counts
     12“time” and when expired causes a lock on itself and the other counters and an
     13interrupt is raised. If any other counter overflows, it continues counting, and
     14no interrupt is raised.
     15
     16The "format" directory describes format of the config (event ID) and config1
     17(AXI filtering) fields of the perf_event_attr structure, see /sys/bus/event_source/
     18devices/imx8_ddr0/format/. The "events" directory describes the events types
     19hardware supported that can be used with perf tool, see /sys/bus/event_source/
     20devices/imx8_ddr0/events/. The "caps" directory describes filter features implemented
     21in DDR PMU, see /sys/bus/events_source/devices/imx8_ddr0/caps/.
     22
     23    .. code-block:: bash
     24
     25        perf stat -a -e imx8_ddr0/cycles/ cmd
     26        perf stat -a -e imx8_ddr0/read/,imx8_ddr0/write/ cmd
     27
     28AXI filtering is only used by CSV modes 0x41 (axid-read) and 0x42 (axid-write)
     29to count reading or writing matches filter setting. Filter setting is various
     30from different DRAM controller implementations, which is distinguished by quirks
     31in the driver. You also can dump info from userspace, filter in "caps" directory
     32indicates whether PMU supports AXI ID filter or not; enhanced_filter indicates
     33whether PMU supports enhanced AXI ID filter or not. Value 0 for un-supported, and
     34value 1 for supported.
     35
     36* With DDR_CAP_AXI_ID_FILTER quirk(filter: 1, enhanced_filter: 0).
     37  Filter is defined with two configuration parts:
     38  --AXI_ID defines AxID matching value.
     39  --AXI_MASKING defines which bits of AxID are meaningful for the matching.
     40
     41      - 0: corresponding bit is masked.
     42      - 1: corresponding bit is not masked, i.e. used to do the matching.
     43
     44  AXI_ID and AXI_MASKING are mapped on DPCR1 register in performance counter.
     45  When non-masked bits are matching corresponding AXI_ID bits then counter is
     46  incremented. Perf counter is incremented if::
     47
     48        AxID && AXI_MASKING == AXI_ID && AXI_MASKING
     49
     50  This filter doesn't support filter different AXI ID for axid-read and axid-write
     51  event at the same time as this filter is shared between counters.
     52
     53  .. code-block:: bash
     54
     55      perf stat -a -e imx8_ddr0/axid-read,axi_mask=0xMMMM,axi_id=0xDDDD/ cmd
     56      perf stat -a -e imx8_ddr0/axid-write,axi_mask=0xMMMM,axi_id=0xDDDD/ cmd
     57
     58  .. note::
     59
     60      axi_mask is inverted in userspace(i.e. set bits are bits to mask), and
     61      it will be reverted in driver automatically. so that the user can just specify
     62      axi_id to monitor a specific id, rather than having to specify axi_mask.
     63
     64  .. code-block:: bash
     65
     66        perf stat -a -e imx8_ddr0/axid-read,axi_id=0x12/ cmd, which will monitor ARID=0x12
     67
     68* With DDR_CAP_AXI_ID_FILTER_ENHANCED quirk(filter: 1, enhanced_filter: 1).
     69  This is an extension to the DDR_CAP_AXI_ID_FILTER quirk which permits
     70  counting the number of bytes (as opposed to the number of bursts) from DDR