      1# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
      2%YAML 1.2
      3---
      4$id: http://devicetree.org/schemas/opp/opp-v2-base.yaml#
      5$schema: http://devicetree.org/meta-schemas/core.yaml#
      6
      7title: Generic OPP (Operating Performance Points) Common Binding
      8
      9maintainers:
     10  - Viresh Kumar <viresh.kumar@linaro.org>
     11
     12description: |
     13  Devices work at voltage-current-frequency combinations and some implementations
     14  have the liberty of choosing these. These combinations are called Operating
     15  Performance Points aka OPPs. This document defines bindings for these OPPs
     16  applicable across wide range of devices. For illustration purpose, this document
     17  uses CPU as a device.
     18
     19  This describes the OPPs belonging to a device.
     20
     21select: false
     22
     23properties:
     24  $nodename:
     25    pattern: '^opp-table(-[a-z0-9]+)?$'
     26
     27  opp-shared:
     28    description:
     29      Indicates that device nodes using this OPP Table Node's phandle switch
     30      their DVFS state together, i.e. they share clock/voltage/current lines.
     31      Missing property means devices have independent clock/voltage/current
     32      lines, but they share OPP tables.
     33    type: boolean
     34
     35patternProperties:
     36  '^opp(-?[0-9]+)*$':
     37    type: object
     38    description:
     39      One or more OPP nodes describing voltage-current-frequency combinations.
     40      Their name isn't significant but their phandle can be used to reference an
     41      OPP. These are mandatory except for the case where the OPP table is
     42      present only to indicate dependency between devices using the opp-shared
     43      property.
     44
     45    properties:
     46      opp-hz:
     47        description:
     48          Frequency in Hz, expressed as a 64-bit big-endian integer. This is a
     49          required property for all device nodes, unless another "required"
     50          property to uniquely identify the OPP nodes exists. Devices like power
     51          domains must have another (implementation dependent) property.
     52
     53      opp-microvolt:
     54        description: |
     55          Voltage for the OPP
     56
     57          A single regulator's voltage is specified with an array of size one or three.
     58          Single entry is for target voltage and three entries are for <target min max>
     59          voltages.
     60
     61          Entries for multiple regulators shall be provided in the same field separated
     62          by angular brackets <>. The OPP binding doesn't provide any provisions to
     63          relate the values to their power supplies or the order in which the supplies
     64          need to be configured and that is left for the implementation specific
     65          binding.
     66
     67          Entries for all regulators shall be of the same size, i.e. either all use a
     68          single value or triplets.
     69        minItems: 1
     70        maxItems: 8   # Should be enough regulators
     71        items:
     72          minItems: 1
     73          maxItems: 3
     74
     75      opp-microamp:
     76        description: |
     77          The maximum current drawn by the device in microamperes considering
     78          system specific parameters (such as transients, process, aging,
     79          maximum operating temperature range etc.) as necessary. This may be
     80          used to set the most efficient regulator operating mode.
     81
     82          Should only be set if opp-microvolt or opp-microvolt-<name> is set for
     83          the OPP.
     84
     85          Entries for multiple regulators shall be provided in the same field
     86          separated by angular brackets <>. If current values aren't required
     87          for a regulator, then it shall be filled with 0. If current values
     88          aren't required for any of the regulators, then this field is not
     89          required. The OPP binding doesn't provide any provisions to relate the
     90          values to their power supplies or the order in which the supplies need
     91          to be configured and that is left for the implementation specific
     92          binding.
     93        minItems: 1
     94        maxItems: 8   # Should be enough regulators
     95
     96      opp-microwatt:
     97        description: |
     98          The power for the OPP in micro-Watts.
     99
    100          Entries for multiple regulators shall be provided in the same field
    101          separated by angular brackets <>. If current values aren't required
    102          for a regulator, then it shall be filled with 0. If power values
    103          aren't required for any of the regulators, then this field is not
    104          required. The OPP binding doesn't provide any provisions to relate the
    105          values to their power supplies or the order in which the supplies need
    106          to be configured and that is left for the implementation specific
    107          binding.
    108        minItems: 1
    109        maxItems: 8   # Should be enough regulators
    110
    111      opp-level:
    112        description:
    113          A value representing the performance level of the device.
    114        $ref: /schemas/types.yaml#/definitions/uint32
    115
    116      opp-peak-kBps:
    117        description:
    118          Peak bandwidth in kilobytes per second, expressed as an array of
    119          32-bit big-endian integers. Each element of the array represents the
    120          peak bandwidth value of each interconnect path. The number of elements
    121          should match the number of interconnect paths.
    122        minItems: 1
    123        maxItems: 32  # Should be enough
    124
    125      opp-avg-kBps:
    126        description:
    127          Average bandwidth in kilobytes per second, expressed as an array
    128          of 32-bit big-endian integers. Each element of the array represents the
    129          average bandwidth value of each interconnect path. The number of elements
    130          should match the number of interconnect paths. This property is only
    131          meaningful in OPP tables where opp-peak-kBps is present.
    132        minItems: 1
    133        maxItems: 32  # Should be enough
    134
    135      clock-latency-ns:
    136        description:
    137          Specifies the maximum possible transition latency (in nanoseconds) for
    138          switching to this OPP from any other OPP.
    139
    140      turbo-mode:
    141        description:
    142          Marks the OPP to be used only for turbo modes. Turbo mode is available
    143          on some platforms, where the device can run over its operating
    144          frequency for a short duration of time limited by the device's power,
    145          current and thermal limits.
    146        type: boolean
    147
    148      opp-suspend:
    149        description:
    150          Marks the OPP to be used during device suspend. If multiple OPPs in
    151          the table have this, the OPP with highest opp-hz will be used.
    152        type: boolean
    153
    154      opp-supported-hw:
    155        description: |
    156          This property allows a platform to enable only a subset of the OPPs
    157          from the larger set present in the OPP table, based on the current
    158          version of the hardware (already known to the operating system).
    159
    160          Each block present in the array of blocks in this property, represents
    161          a sub-group of hardware versions supported by the OPP. i.e. <sub-group
    162          A>, <sub-group B>, etc. The OPP will be enabled if _any_ of these
    163          sub-groups match the hardware's version.
    164
    165          Each sub-group is a platform defined array representing the hierarchy
    166          of hardware versions supported by the platform. For a platform with
    167          three hierarchical levels of version (X.Y.Z), this field shall look
    168          like
    169
    170          opp-supported-hw = <X1 Y1 Z1>, <X2 Y2 Z2>, <X3 Y3 Z3>.
    171
    172          Each level (eg. X1) in version hierarchy is represented by a 32 bit
    173          value, one bit per version and so there can be maximum 32 versions per
    174          level. Logical AND (&) operation is performed for each level with the
    175          hardware's level version and a non-zero output for _all_ the levels in
    176          a sub-group means the OPP is supported by hardware. A value of
    177          0xFFFFFFFF for each level in the sub-group will enable the OPP for all
    178          versions for the hardware.
    179        $ref: /schemas/types.yaml#/definitions/uint32-matrix
    180        maxItems: 32
    181        items:
    182          minItems: 1
    183          maxItems: 4
    184
    185      required-opps:
    186        description:
    187          This contains phandle to an OPP node in another device's OPP table. It
    188          may contain an array of phandles, where each phandle points to an OPP
    189          of a different device. It should not contain multiple phandles to the
    190          OPP nodes in the same OPP table. This specifies the minimum required
    191          OPP of the device(s), whose OPP's phandle is present in this property,
    192          for the functioning of the current device at the current OPP (where
    193          this property is present).
    194        $ref: /schemas/types.yaml#/definitions/phandle-array
    195        items:
    196          maxItems: 1
    197
    198    patternProperties:
    199      '^opp-microvolt-':
    200        description:
    201          Named opp-microvolt property. This is exactly similar to the above
    202          opp-microvolt property, but allows multiple voltage ranges to be
    203          provided for the same OPP. At runtime, the platform can pick a <name>
    204          and matching opp-microvolt-<name> property will be enabled for all
    205          OPPs. If the platform doesn't pick a specific <name> or the <name>
    206          doesn't match with any opp-microvolt-<name> properties, then
    207          opp-microvolt property shall be used, if present.
    208        $ref: /schemas/types.yaml#/definitions/uint32-matrix
    209        minItems: 1
    210        maxItems: 8   # Should be enough regulators
    211        items:
    212          minItems: 1
    213          maxItems: 3
    214
    215      '^opp-microamp-':
    216        description:
    217          Named opp-microamp property. Similar to opp-microvolt-<name> property,
    218          but for microamp instead.
    219        $ref: /schemas/types.yaml#/definitions/uint32-array
    220        minItems: 1
    221        maxItems: 8   # Should be enough regulators
    222
    223      '^opp-microwatt':
    224        description:
    225          Named opp-microwatt property. Similar to opp-microamp property,
    226          but for microwatt instead.
    227        $ref: /schemas/types.yaml#/definitions/uint32-array
    228        minItems: 1
    229        maxItems: 8   # Should be enough regulators
    230
    231    dependencies:
    232      opp-avg-kBps: [ opp-peak-kBps ]
    233
    234required: