      1# SPDX-License-Identifier: GPL-2.0
      2%YAML 1.2
      3---
      4$id: http://devicetree.org/schemas/regulator/regulator.yaml#
      5$schema: http://devicetree.org/meta-schemas/core.yaml#
      6
      7title: Voltage/Current Regulators
      8
      9maintainers:
     10  - Liam Girdwood <lgirdwood@gmail.com>
     11  - Mark Brown <broonie@kernel.org>
     12
     13properties:
     14  regulator-name:
     15    description: A string used as a descriptive name for regulator outputs
     16    $ref: "/schemas/types.yaml#/definitions/string"
     17
     18  regulator-min-microvolt:
     19    description: smallest voltage consumers may set
     20
     21  regulator-max-microvolt:
     22    description: largest voltage consumers may set
     23
     24  regulator-microvolt-offset:
     25    description: Offset applied to voltages to compensate for voltage drops
     26
     27  regulator-min-microamp:
     28    description: smallest current consumers may set
     29
     30  regulator-max-microamp:
     31    description: largest current consumers may set
     32
     33  regulator-input-current-limit-microamp:
     34    description: maximum input current regulator allows
     35
     36  regulator-always-on:
     37    description: boolean, regulator should never be disabled
     38    type: boolean
     39
     40  regulator-boot-on:
     41    description: bootloader/firmware enabled regulator.
     42      It's expected that this regulator was left on by the bootloader.
     43      If the bootloader didn't leave it on then OS should turn it on
     44      at boot but shouldn't prevent it from being turned off later.
     45      This property is intended to only be used for regulators where
     46      software cannot read the state of the regulator.
     47    type: boolean
     48
     49  regulator-allow-bypass:
     50    description: allow the regulator to go into bypass mode
     51    type: boolean
     52
     53  regulator-allow-set-load:
     54    description: allow the regulator performance level to be configured
     55    type: boolean
     56
     57  regulator-ramp-delay:
     58    description: ramp delay for regulator(in uV/us) For hardware which supports
     59      disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay
     60      = <0>) for disabling ramp delay.
     61    $ref: "/schemas/types.yaml#/definitions/uint32"
     62
     63  regulator-enable-ramp-delay:
     64    description: The time taken, in microseconds, for the supply rail to
     65      reach the target voltage, plus/minus whatever tolerance the board
     66      design requires. This property describes the total system ramp time
     67      required due to the combination of internal ramping of the regulator
     68      itself, and board design issues such as trace capacitance and load
     69      on the supply.
     70    $ref: "/schemas/types.yaml#/definitions/uint32"
     71
     72  regulator-settling-time-us:
     73    description: Settling time, in microseconds, for voltage change if regulator
     74      have the constant time for any level voltage change. This is useful
     75      when regulator have exponential voltage change.
     76
     77  regulator-settling-time-up-us:
     78    description: Settling time, in microseconds, for voltage increase if
     79      the regulator needs a constant time to settle after voltage increases
     80      of any level. This is useful for regulators with exponential voltage
     81      changes.
     82
     83  regulator-settling-time-down-us:
     84    description: Settling time, in microseconds, for voltage decrease if
     85      the regulator needs a constant time to settle after voltage decreases
     86      of any level. This is useful for regulators with exponential voltage
     87      changes.
     88
     89  regulator-soft-start:
     90    description: Enable soft start so that voltage ramps slowly
     91    type: boolean
     92
     93  regulator-initial-mode:
     94    description: initial operating mode. The set of possible operating modes
     95      depends on the capabilities of every hardware so each device binding
     96      documentation explains which values the regulator supports.
     97    $ref: "/schemas/types.yaml#/definitions/uint32"
     98
     99  regulator-allowed-modes:
    100    description: list of operating modes that software is allowed to configure
    101      for the regulator at run-time.  Elements may be specified in any order.
    102      The set of possible operating modes depends on the capabilities of
    103      every hardware so each device binding document explains which values
    104      the regulator supports.
    105    $ref: "/schemas/types.yaml#/definitions/uint32-array"
    106
    107  regulator-system-load:
    108    description: Load in uA present on regulator that is not captured by
    109      any consumer request.
    110    $ref: "/schemas/types.yaml#/definitions/uint32"
    111
    112  regulator-pull-down:
    113    description: Enable pull down resistor when the regulator is disabled.
    114    type: boolean
    115
    116  regulator-over-current-protection:
    117    description: Enable over current protection.
    118    type: boolean
    119
    120  regulator-oc-protection-microamp:
    121    description: Set over current protection limit. This is a limit where
    122      hardware performs emergency shutdown. Zero can be passed to disable
    123      protection and value '1' indicates that protection should be enabled but
    124      limit setting can be omitted.
    125
    126  regulator-oc-error-microamp:
    127    description: Set over current error limit. This is a limit where part of
    128      the hardware propably is malfunctional and damage prevention is requested.
    129      Zero can be passed to disable error detection and value '1' indicates
    130      that detection should be enabled but limit setting can be omitted.
    131
    132  regulator-oc-warn-microamp:
    133    description: Set over current warning limit. This is a limit where hardware
    134      is assumed still to be functional but approaching limit where it gets
    135      damaged. Recovery actions should be initiated. Zero can be passed to
    136      disable detection and value '1' indicates that detection should
    137      be enabled but limit setting can be omitted.
    138
    139  regulator-ov-protection-microvolt:
    140    description: Set over voltage protection limit. This is a limit where
    141      hardware performs emergency shutdown. Zero can be passed to disable
    142      protection and value '1' indicates that protection should be enabled but
    143      limit setting can be omitted. Limit is given as microvolt offset from
    144      voltage set to regulator.
    145
    146  regulator-ov-error-microvolt:
    147    description: Set over voltage error limit. This is a limit where part of
    148      the hardware propably is malfunctional and damage prevention is requested
    149      Zero can be passed to disable error detection and value '1' indicates
    150      that detection should be enabled but limit setting can be omitted. Limit
    151      is given as microvolt offset from voltage set to regulator.
    152
    153  regulator-ov-warn-microvolt:
    154    description: Set over voltage warning limit. This is a limit where hardware
    155      is assumed still to be functional but approaching limit where it gets
    156      damaged. Recovery actions should be initiated. Zero can be passed to
    157      disable detection and value '1' indicates that detection should
    158      be enabled but limit setting can be omitted. Limit is given as microvolt
    159      offset from voltage set to regulator.
    160
    161  regulator-uv-protection-microvolt:
    162    description: Set over under voltage protection limit. This is a limit where
    163      hardware performs emergency shutdown. Zero can be passed to disable
    164      protection and value '1' indicates that protection should be enabled but
    165      limit setting can be omitted. Limit is given as microvolt offset from
    166      voltage set to regulator.
    167
    168  regulator-uv-error-microvolt:
    169    description: Set under voltage error limit. This is a limit where part of
    170      the hardware propably is malfunctional and damage prevention is requested
    171      Zero can be passed to disable error detection and value '1' indicates
    172      that detection should be enabled but limit setting can be omitted. Limit
    173      is given as microvolt offset from voltage set to regulator.
    174
    175  regulator-uv-warn-microvolt:
    176    description: Set over under voltage warning limit. This is a limit where
    177      hardware is assumed still to be functional but approaching limit where
    178      it gets damaged. Recovery actions should be initiated. Zero can be passed
    179      to disable detection and value '1' indicates that detection should
    180      be enabled but limit setting can be omitted. Limit is given as microvolt
    181      offset from voltage set to regulator.
    182
    183  regulator-temp-protection-kelvin:
    184    description: Set over temperature protection limit. This is a limit where
    185      hardware performs emergency shutdown. Zero can be passed to disable
    186      protection and value '1' indicates that protection should be enabled but
    187      limit setting can be omitted.
    188
    189  regulator-temp-error-kelvin:
    190    description: Set over temperature error limit. This is a limit where part of
    191      the hardware propably is malfunctional and damage prevention is requested
    192      Zero can be passed to disable error detection and value '1' indicates
    193      that detection should be enabled but limit setting can be omitted.
    194
    195  regulator-temp-warn-kelvin:
    196    description: Set over temperature warning limit. This is a limit where
    197      hardware is assumed still to be functional but approaching limit where it
    198      gets damaged. Recovery actions should be initiated. Zero can be passed to
    199      disable detection and value '1' indicates that detection should
    200      be enabled but limit setting can be omitted.
    201
    202  regulator-active-discharge:
    203    description: |
    204      tristate, enable/disable active discharge of regulators. The values are:
    205      0: Disable active discharge.
    206      1: Enable active discharge.
    207      Absence of this property will leave configuration to default.
    208    $ref: "/schemas/types.yaml#/definitions/uint32"
    209    enum: [0, 1]
    210
    211  regulator-coupled-with:
    212    description: Regulators with which the regulator is coupled. The linkage
    213      is 2-way - all coupled regulators should be linked with each other.
    214      A regulator should not be coupled with its supplier.
    215    $ref: "/schemas/types.yaml#/definitions/phandle-array"
    216    items:
    217      maxItems: 1
    218
    219  regulator-coupled-max-spread:
    220    description: Array of maximum spread between voltages of coupled regulators
    221      in microvolts, each value in the array relates to the corresponding
    222      couple specified by the regulator-coupled-with property.
    223    $ref: "/schemas/types.yaml#/definitions/uint32-array"
    224
    225  regulator-max-step-microvolt:
    226    description: Maximum difference between current and target voltages
    227      that can be changed safely in a single step.
    228
    229patternProperties:
    230  ".*-supply$":
    231    description: Input supply phandle(s) for this node
    232
    233  regulator-state-(standby|mem|disk):
    234    type: object
    235    description:
    236      sub-nodes for regulator state in Standby, Suspend-to-RAM, and
    237      Suspend-to-DISK modes. Equivalent with standby, mem, and disk Linux
    238      sleep states.
    239
    240    properties:
    241      regulator-on-in-suspend:
    242        description: regulator should be on in suspend state.
    243        type: boolean
    244
    245      regulator-off-in-suspend:
    246        description: regulator should be off in suspend state.
    247        type: boolean
    248
    249      regulator-suspend-min-microvolt:
    250        description: minimum voltage may be set in suspend state.
    251
    252      regulator-suspend-max-microvolt:
    253        description: maximum voltage may be set in suspend state.
    254
    255      regulator-suspend-microvolt:
    256        description: the default voltage which regulator would be set in
    257          suspend. This property is now deprecated, instead setting voltage
    258          for suspend mode via the API which regulator driver provides is
    259          recommended.
    260
    261      regulator-changeable-in-suspend:
    262        description: whether the default voltage and the regulator on/off
    263          in suspend can be changed in runtime.
    264        type: boolean
    265
    266      regulator-mode:
    267        description: operating mode in the given suspend state. The set
    268          of possible operating modes depends on the capabilities of every
    269          hardware so the valid modes are documented on each regulator device
    270          tree binding document.
    271        $ref: "/schemas/types.yaml#/definitions/uint32"
    272
    273    additionalProperties: false
    274
    275additionalProperties: true
    276
    277examples:
    278  - |
    279    xyzreg: regulator {
    280      regulator-min-microvolt = <1000000>;
    281      regulator-max-microvolt = <2500000>;
    282      regulator-always-on;
    283      vin-supply = <&vin>;
    284
    285      regulator-state-mem {