cachepc-linux

Fork of AMDESE/linux with modifications for CachePC side-channel attack
git clone https://git.sinitax.com/sinitax/cachepc-linux
Log | Files | Refs | README | LICENSE | sfeed.txt

f71882fg.rst (5557B)


      1Kernel driver f71882fg
      2======================
      3
      4Supported chips:
      5
      6  * Fintek F71808E
      7
      8    Prefix: 'f71808e'
      9
     10    Addresses scanned: none, address read from Super I/O config space
     11
     12    Datasheet: Not public
     13
     14  * Fintek F71808A
     15
     16    Prefix: 'f71808a'
     17
     18    Addresses scanned: none, address read from Super I/O config space
     19
     20    Datasheet: Not public
     21
     22  * Fintek F71858FG
     23
     24    Prefix: 'f71858fg'
     25
     26    Addresses scanned: none, address read from Super I/O config space
     27
     28    Datasheet: Available from the Fintek website
     29
     30  * Fintek F71862FG and F71863FG
     31
     32    Prefix: 'f71862fg'
     33
     34    Addresses scanned: none, address read from Super I/O config space
     35
     36    Datasheet: Available from the Fintek website
     37
     38  * Fintek F71869F and F71869E
     39
     40    Prefix: 'f71869'
     41
     42    Addresses scanned: none, address read from Super I/O config space
     43
     44    Datasheet: Available from the Fintek website
     45
     46  * Fintek F71869A
     47
     48    Prefix: 'f71869a'
     49
     50    Addresses scanned: none, address read from Super I/O config space
     51
     52    Datasheet: Not public
     53
     54  * Fintek F71882FG and F71883FG
     55
     56    Prefix: 'f71882fg'
     57
     58    Addresses scanned: none, address read from Super I/O config space
     59
     60    Datasheet: Available from the Fintek website
     61
     62  * Fintek F71889FG
     63
     64    Prefix: 'f71889fg'
     65
     66    Addresses scanned: none, address read from Super I/O config space
     67
     68    Datasheet: Available from the Fintek website
     69
     70  * Fintek F71889ED
     71
     72    Prefix: 'f71889ed'
     73
     74    Addresses scanned: none, address read from Super I/O config space
     75
     76    Datasheet: Should become available on the Fintek website soon
     77
     78  * Fintek F71889A
     79
     80    Prefix: 'f71889a'
     81
     82    Addresses scanned: none, address read from Super I/O config space
     83
     84    Datasheet: Should become available on the Fintek website soon
     85
     86  * Fintek F8000
     87
     88    Prefix: 'f8000'
     89
     90    Addresses scanned: none, address read from Super I/O config space
     91
     92    Datasheet: Not public
     93
     94  * Fintek F81801U
     95
     96    Prefix: 'f71889fg'
     97
     98    Addresses scanned: none, address read from Super I/O config space
     99
    100    Datasheet: Not public
    101
    102    Note:
    103	  This is the 64-pin variant of the F71889FG, they have the
    104	  same device ID and are fully compatible as far as hardware
    105	  monitoring is concerned.
    106
    107  * Fintek F81865F
    108
    109    Prefix: 'f81865f'
    110
    111    Addresses scanned: none, address read from Super I/O config space
    112
    113    Datasheet: Available from the Fintek website
    114
    115Author: Hans de Goede <hdegoede@redhat.com>
    116
    117
    118Description
    119-----------
    120
    121Fintek F718xx/F8000 Super I/O chips include complete hardware monitoring
    122capabilities. They can monitor up to 9 voltages, 4 fans and 3 temperature
    123sensors.
    124
    125These chips also have fan controlling features, using either DC or PWM, in
    126three different modes (one manual, two automatic).
    127
    128The driver assumes that no more than one chip is present, which seems
    129reasonable.
    130
    131
    132Monitoring
    133----------
    134
    135The Voltage, Fan and Temperature Monitoring uses the standard sysfs
    136interface as documented in sysfs-interface, without any exceptions.
    137
    138
    139Fan Control
    140-----------
    141
    142Both PWM (pulse-width modulation) and DC fan speed control methods are
    143supported. The right one to use depends on external circuitry on the
    144motherboard, so the driver assumes that the BIOS set the method
    145properly.
    146
    147Note that the lowest numbered temperature zone trip point corresponds to
    148the border between the highest and one but highest temperature zones, and
    149vica versa. So the temperature zone trip points 1-4 (or 1-2) go from high temp
    150to low temp! This is how things are implemented in the IC, and the driver
    151mimics this.
    152
    153There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC
    154voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM
    155mode where the actual RPM of the fan (as measured) is controlled and the speed
    156gets specified as 0-100% of the fan#_full_speed file.
    157
    158Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a
    159whole lot of a difference when modifying fan control settings. The only
    160important difference is that in RPM mode the 0-100% controls the fan speed
    161between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs
    162RPM mode, it will also set fan#_full_speed properly, if it does not then
    163fan control will not work properly, unless you set a sane fan#_full_speed
    164value yourself.
    165
    166Switching between these modes requires re-initializing a whole bunch of
    167registers, so the mode which the BIOS has set is kept. The mode is
    168printed when loading the driver.
    169
    170Three different fan control modes are supported; the mode number is written
    171to the pwm#_enable file. Note that not all modes are supported on all
    172chips, and some modes may only be available in RPM / PWM mode.
    173Writing an unsupported mode will result in an invalid parameter error.
    174
    175* 1: Manual mode
    176  You ask for a specific PWM duty cycle / DC voltage or a specific % of
    177  fan#_full_speed by writing to the pwm# file. This mode is only
    178  available on the F71858FG / F8000 if the fan channel is in RPM mode.
    179
    180* 2: Normal auto mode
    181  You can define a number of temperature/fan speed trip points, which % the
    182  fan should run at at this temp and which temp a fan should follow using the
    183  standard sysfs interface. The number and type of trip points is chip
    184  depended, see which files are available in sysfs.
    185  Fan/PWM channel 3 of the F8000 is always in this mode!
    186
    187* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode)
    188  The fan speed is regulated to keep the temp the fan is mapped to between
    189  temp#_auto_point2_temp and temp#_auto_point3_temp.
    190
    191All of the automatic modes require that pwm1 corresponds to fan1, pwm2 to
    192fan2 and pwm3 to fan3.