cachepc-linux

Fork of AMDESE/linux with modifications for CachePC side-channel attack
git clone https://git.sinitax.com/sinitax/cachepc-linux
Log | Files | Refs | README | LICENSE | sfeed.txt

cpsw_switchdev.rst (6416B)


      1.. SPDX-License-Identifier: GPL-2.0
      2
      3======================================================
      4Texas Instruments CPSW switchdev based ethernet driver
      5======================================================
      6
      7:Version: 2.0
      8
      9Port renaming
     10=============
     11
     12On older udev versions renaming of ethX to swXpY will not be automatically
     13supported
     14
     15In order to rename via udev::
     16
     17    ip -d link show dev sw0p1 | grep switchid
     18
     19    SUBSYSTEM=="net", ACTION=="add", ATTR{phys_switch_id}==<switchid>, \
     20	    ATTR{phys_port_name}!="", NAME="sw0$attr{phys_port_name}"
     21
     22
     23Dual mac mode
     24=============
     25
     26- The new (cpsw_new.c) driver is operating in dual-emac mode by default, thus
     27  working as 2 individual network interfaces. Main differences from legacy CPSW
     28  driver are:
     29
     30 - optimized promiscuous mode: The P0_UNI_FLOOD (both ports) is enabled in
     31   addition to ALLMULTI (current port) instead of ALE_BYPASS.
     32   So, Ports in promiscuous mode will keep possibility of mcast and vlan
     33   filtering, which is provides significant benefits when ports are joined
     34   to the same bridge, but without enabling "switch" mode, or to different
     35   bridges.
     36 - learning disabled on ports as it make not too much sense for
     37   segregated ports - no forwarding in HW.
     38 - enabled basic support for devlink.
     39
     40   ::
     41
     42	devlink dev show
     43		platform/48484000.switch
     44
     45	devlink dev param show
     46	platform/48484000.switch:
     47	name switch_mode type driver-specific
     48	values:
     49		cmode runtime value false
     50	name ale_bypass type driver-specific
     51	values:
     52		cmode runtime value false
     53
     54Devlink configuration parameters
     55================================
     56
     57See Documentation/networking/devlink/ti-cpsw-switch.rst
     58
     59Bridging in dual mac mode
     60=========================
     61
     62The dual_mac mode requires two vids to be reserved for internal purposes,
     63which, by default, equal CPSW Port numbers. As result, bridge has to be
     64configured in vlan unaware mode or default_pvid has to be adjusted::
     65
     66	ip link add name br0 type bridge
     67	ip link set dev br0 type bridge vlan_filtering 0
     68	echo 0 > /sys/class/net/br0/bridge/default_pvid
     69	ip link set dev sw0p1 master br0
     70	ip link set dev sw0p2 master br0
     71
     72or::
     73
     74	ip link add name br0 type bridge
     75	ip link set dev br0 type bridge vlan_filtering 0
     76	echo 100 > /sys/class/net/br0/bridge/default_pvid
     77	ip link set dev br0 type bridge vlan_filtering 1
     78	ip link set dev sw0p1 master br0
     79	ip link set dev sw0p2 master br0
     80
     81Enabling "switch"
     82=================
     83
     84The Switch mode can be enabled by configuring devlink driver parameter
     85"switch_mode" to 1/true::
     86
     87	devlink dev param set platform/48484000.switch \
     88	name switch_mode value 1 cmode runtime
     89
     90This can be done regardless of the state of Port's netdev devices - UP/DOWN, but
     91Port's netdev devices have to be in UP before joining to the bridge to avoid
     92overwriting of bridge configuration as CPSW switch driver copletly reloads its
     93configuration when first Port changes its state to UP.
     94
     95When the both interfaces joined the bridge - CPSW switch driver will enable
     96marking packets with offload_fwd_mark flag unless "ale_bypass=0"
     97
     98All configuration is implemented via switchdev API.
     99
    100Bridge setup
    101============
    102
    103::
    104
    105	devlink dev param set platform/48484000.switch \
    106	name switch_mode value 1 cmode runtime
    107
    108	ip link add name br0 type bridge
    109	ip link set dev br0 type bridge ageing_time 1000
    110	ip link set dev sw0p1 up
    111	ip link set dev sw0p2 up
    112	ip link set dev sw0p1 master br0
    113	ip link set dev sw0p2 master br0
    114
    115	[*] bridge vlan add dev br0 vid 1 pvid untagged self
    116
    117	[*] if vlan_filtering=1. where default_pvid=1
    118
    119	Note. Steps [*] are mandatory.
    120
    121
    122On/off STP
    123==========
    124
    125::
    126
    127	ip link set dev BRDEV type bridge stp_state 1/0
    128
    129VLAN configuration
    130==================
    131
    132::
    133
    134  bridge vlan add dev br0 vid 1 pvid untagged self <---- add cpu port to VLAN 1
    135
    136Note. This step is mandatory for bridge/default_pvid.
    137
    138Add extra VLANs
    139===============
    140
    141 1. untagged::
    142
    143	bridge vlan add dev sw0p1 vid 100 pvid untagged master
    144	bridge vlan add dev sw0p2 vid 100 pvid untagged master
    145	bridge vlan add dev br0 vid 100 pvid untagged self <---- Add cpu port to VLAN100
    146
    147 2. tagged::
    148
    149	bridge vlan add dev sw0p1 vid 100 master
    150	bridge vlan add dev sw0p2 vid 100 master
    151	bridge vlan add dev br0 vid 100 pvid tagged self <---- Add cpu port to VLAN100
    152
    153FDBs
    154----
    155
    156FDBs are automatically added on the appropriate switch port upon detection
    157
    158Manually adding FDBs::
    159
    160    bridge fdb add aa:bb:cc:dd:ee:ff dev sw0p1 master vlan 100
    161    bridge fdb add aa:bb:cc:dd:ee:fe dev sw0p2 master <---- Add on all VLANs
    162
    163MDBs
    164----
    165
    166MDBs are automatically added on the appropriate switch port upon detection
    167
    168Manually adding MDBs::
    169
    170  bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent vid 100
    171  bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent <---- Add on all VLANs
    172
    173Multicast flooding
    174==================
    175CPU port mcast_flooding is always on
    176
    177Turning flooding on/off on swithch ports:
    178bridge link set dev sw0p1 mcast_flood on/off
    179
    180Access and Trunk port
    181=====================
    182
    183::
    184
    185 bridge vlan add dev sw0p1 vid 100 pvid untagged master
    186 bridge vlan add dev sw0p2 vid 100 master
    187
    188
    189 bridge vlan add dev br0 vid 100 self
    190 ip link add link br0 name br0.100 type vlan id 100
    191
    192Note. Setting PVID on Bridge device itself working only for
    193default VLAN (default_pvid).
    194
    195NFS
    196===
    197
    198The only way for NFS to work is by chrooting to a minimal environment when
    199switch configuration that will affect connectivity is needed.
    200Assuming you are booting NFS with eth1 interface(the script is hacky and
    201it's just there to prove NFS is doable).
    202
    203setup.sh::
    204
    205	#!/bin/sh
    206	mkdir proc
    207	mount -t proc none /proc
    208	ifconfig br0  > /dev/null
    209	if [ $? -ne 0 ]; then
    210		echo "Setting up bridge"
    211		ip link add name br0 type bridge
    212		ip link set dev br0 type bridge ageing_time 1000
    213		ip link set dev br0 type bridge vlan_filtering 1
    214
    215		ip link set eth1 down
    216		ip link set eth1 name sw0p1
    217		ip link set dev sw0p1 up
    218		ip link set dev sw0p2 up
    219		ip link set dev sw0p2 master br0
    220		ip link set dev sw0p1 master br0
    221		bridge vlan add dev br0 vid 1 pvid untagged self
    222		ifconfig sw0p1 0.0.0.0
    223		udhchc -i br0
    224	fi
    225	umount /proc
    226
    227run_nfs.sh:::
    228
    229	#!/bin/sh
    230	mkdir /tmp/root/bin -p
    231	mkdir /tmp/root/lib -p
    232
    233	cp -r /lib/ /tmp/root/
    234	cp -r /bin/ /tmp/root/
    235	cp /sbin/ip /tmp/root/bin
    236	cp /sbin/bridge /tmp/root/bin
    237	cp /sbin/ifconfig /tmp/root/bin
    238	cp /sbin/udhcpc /tmp/root/bin
    239	cp /path/to/setup.sh /tmp/root/bin
    240	chroot /tmp/root/ busybox sh /bin/setup.sh
    241