cachepc-linux

Fork of AMDESE/linux with modifications for CachePC side-channel attack
git clone https://git.sinitax.com/sinitax/cachepc-linux
Log | Files | Refs | README | LICENSE | sfeed.txt

link_power_management_policy.rst (1003B)


      1.. SPDX-License-Identifier: GPL-2.0
      2
      3==========================
      4Link Power Managent Policy
      5==========================
      6
      7This parameter allows the user to set the link (interface) power management.
      8There are 3 possible options:
      9
     10=====================   =====================================================
     11Value			Effect
     12=====================   =====================================================
     13min_power		Tell the controller to try to make the link use the
     14			least possible power when possible.  This may
     15			sacrifice some performance due to increased latency
     16			when coming out of lower power states.
     17
     18max_performance		Generally, this means no power management.  Tell
     19			the controller to have performance be a priority
     20			over power management.