cachepc-linux

Fork of AMDESE/linux with modifications for CachePC side-channel attack
git clone https://git.sinitax.com/sinitax/cachepc-linux
Log | Files | Refs | README | LICENSE | sfeed.txt

intel-hfi.rst (3576B)


      1.. SPDX-License-Identifier: GPL-2.0
      2
      3============================================================
      4Hardware-Feedback Interface for scheduling on Intel Hardware
      5============================================================
      6
      7Overview
      8--------
      9
     10Intel has described the Hardware Feedback Interface (HFI) in the Intel 64 and
     11IA-32 Architectures Software Developer's Manual (Intel SDM) Volume 3 Section
     1214.6 [1]_.
     13
     14The HFI gives the operating system a performance and energy efficiency
     15capability data for each CPU in the system. Linux can use the information from
     16the HFI to influence task placement decisions.
     17
     18The Hardware Feedback Interface
     19-------------------------------
     20
     21The Hardware Feedback Interface provides to the operating system information
     22about the performance and energy efficiency of each CPU in the system. Each
     23capability is given as a unit-less quantity in the range [0-255]. Higher values
     24indicate higher capability. Energy efficiency and performance are reported in
     25separate capabilities. Even though on some systems these two metrics may be
     26related, they are specified as independent capabilities in the Intel SDM.
     27
     28These capabilities may change at runtime as a result of changes in the
     29operating conditions of the system or the action of external factors. The rate
     30at which these capabilities are updated is specific to each processor model. On
     31some models, capabilities are set at boot time and never change. On others,
     32capabilities may change every tens of milliseconds. For instance, a remote
     33mechanism may be used to lower Thermal Design Power. Such change can be
     34reflected in the HFI. Likewise, if the system needs to be throttled due to
     35excessive heat, the HFI may reflect reduced performance on specific CPUs.
     36
     37The kernel or a userspace policy daemon can use these capabilities to modify
     38task placement decisions. For instance, if either the performance or energy
     39capabilities of a given logical processor becomes zero, it is an indication that
     40the hardware recommends to the operating system to not schedule any tasks on
     41that processor for performance or energy efficiency reasons, respectively.
     42
     43Implementation details for Linux
     44--------------------------------
     45
     46The infrastructure to handle thermal event interrupts has two parts. In the
     47Local Vector Table of a CPU's local APIC, there exists a register for the
     48Thermal Monitor Register. This register controls how interrupts are delivered
     49to a CPU when the thermal monitor generates and interrupt. Further details
     50can be found in the Intel SDM Vol. 3 Section 10.5 [1]_.
     51
     52The thermal monitor may generate interrupts per CPU or per package. The HFI
     53generates package-level interrupts. This monitor is configured and initialized
     54via a set of machine-specific registers. Specifically, the HFI interrupt and
     55status are controlled via designated bits in the IA32_PACKAGE_THERM_INTERRUPT
     56and IA32_PACKAGE_THERM_STATUS registers, respectively. There exists one HFI
     57table per package. Further details can be found in the Intel SDM Vol. 3
     58Section 14.9 [1]_.
     59
     60The hardware issues an HFI interrupt after updating the HFI table and is ready
     61for the operating system to consume it. CPUs receive such interrupt via the
     62thermal entry in the Local APIC's Local Vector Table.
     63
     64When servicing such interrupt, the HFI driver parses the updated table and
     65relays the update to userspace using the thermal notification framework. Given
     66that there may be many HFI updates every second, the updates relayed to
     67userspace are throttled at a rate of CONFIG_HZ jiffies.