      1Confidential Guest Support
      2==========================
      3
      4Traditionally, hypervisors such as QEMU have complete access to a
      5guest's memory and other state, meaning that a compromised hypervisor
      6can compromise any of its guests.  A number of platforms have added
      7mechanisms in hardware and/or firmware which give guests at least some
      8protection from a compromised hypervisor.  This is obviously
      9especially desirable for public cloud environments.
     10
     11These mechanisms have different names and different modes of
     12operation, but are often referred to as Secure Guests or Confidential
     13Guests.  We use the term "Confidential Guest Support" to distinguish
     14this from other aspects of guest security (such as security against
     15attacks from other guests, or from network sources).
     16
     17Running a Confidential Guest
     18----------------------------
     19
     20To run a confidential guest you need to add two command line parameters:
     21
     221. Use "-object" to create a "confidential guest support" object.  The
     23   type and parameters will vary with the specific mechanism to be
     24   used
     252. Set the "confidential-guest-support" machine parameter to the ID of
     26   the object from (1).
     27
     28Example (for AMD SEV)::
     29
     30    qemu-system-x86_64 \
     31        <other parameters> \
     32        -machine ...,confidential-guest-support=sev0 \
     33        -object sev-guest,id=sev0,cbitpos=47,reduced-phys-bits=1
     34
     35Supported mechanisms
     36--------------------
     37
     38Currently supported confidential guest mechanisms are:
     39
     40AMD Secure Encrypted Virtualization (SEV)
     41    docs/amd-memory-encryption.txt
     42
     43POWER Protected Execution Facility (PEF)
     44    docs/papr-pef.txt